Wiki
Water problems

RO/DI output wrong or filters spent

Also calledRO output TDS highDI resinRO membrane replacementchlorine after carbon blockRO TDS creepRO/DI not making pure water

A reverse osmosis (RO) or RO/deionisation (DI) unit that should make near-pure water gives a high TDS reading, shows chlorine after a cartridge change, or has worn-out parts. TDS means total dissolved solids, a quick reading of how much is dissolved in the water. It is rarely urgent, but chlorine in the output can harm fish and shrimp.

How urgentNot urgent

Mostly a looks problem. Fix it steadily.

What you see

  • A TDS meter reads higher on the RO output than it used to
  • A TDS reading above zero after the DI stage
  • A chlorine test shows chlorine in the water after you changed the carbon block or DI cartridge
  • The unit makes water slowly, or the DI resin has changed colour all the way through

Could it be something else?

  • pH crash and swings: Pure RO water with no minerals added back can let pH swing or crash in the tank; this guide is about the unit itself
  • Chlorine and chloramine: That guide covers treating tap water going into the tank; this one covers chlorine getting through an RO unit

Why it happens

  1. Worn or damaged membraneA worn membrane lets more dissolved material through. Chlorine attacks the membrane, and the first signs are lost flow and then more salt passing through. One water-treatment company quotes three to five years as a normal life, but chlorine can ruin one in weeks to months.
  2. Low inlet pressureThe more pressure pushing water through the membrane, the lower the TDS of the output, so low feed pressure raises the reading even on a good membrane.
  3. Spent DI resinDI resin removes the last dissolved material. It runs out faster when the membrane lets more through, so a worn membrane also uses up resin quickly.
  4. Carbon stage not stopping chlorineActivated carbon is what removes chlorine before the membrane, so spent, bypassed or wrongly fitted carbon lets it through. Chloramine releases small amounts of free chlorine too, so it needs removing before the membrane as well.
  5. A reading mistakeA TDS meter that is dirty, uncalibrated, or used in water straight after a flush can mislead. Rinse the probe and measure again.
Step by step

Fix it now

Safety first: if a step uses a medicine, treatment or salt, follow the product label and never go above the labelled dose. Check the label for animals it can harm, such as shrimp, snails and scaleless fish, and for whether to remove carbon. If you are unsure, or animals keep dying, ask an aquatic vet.

  1. Keep the output water away from fish and shrimp until it tests clean, or treat it as you would tap water, with a conditioner that handles chlorine and chloramine, following the label
  2. Turn off the feed water and release the pressure before you open any housing, and mop up spills
  3. Measure TDS three times: tap water going in, water after the membrane (before the DI cartridge), and water after the DI cartridge
  4. Work out the membrane's rejection: (1 minus output TDS divided by tap TDS) times 100, and compare it with the rejection in your membrane's data sheet
  5. If rejection is low, check inlet pressure first, then test for chlorine after the carbon stage, replace any spent carbon, and only then replace the membrane
  6. If the membrane is fine but the reading after the DI stage is above zero, replace the DI resin and check the cartridge is fitted the right way round
  7. After any change, flush the new parts as your maker's manual says and throw that water away

Stop it coming back

  • Change the carbon stage on your maker's schedule so chlorine never reaches the membrane
  • Test for chlorine after the carbon stage now and then
  • Log tap TDS and output TDS each month so a slow decline shows early
  • Keep inlet pressure in the range your unit's manual asks for

Common questions

What is going on with my RO system? Output TDS is higher than it should be.
Measure TDS before the membrane and after it, then work out rejection. A low figure points to a worn membrane, low inlet pressure or chlorine damage. If rejection is fine, the extra reading is probably coming from the DI stage.
Why do I get chlorine after replacing the carbon block and DI cartridge?
First check that the cartridges are seated properly and the water is not bypassing the carbon, and follow your maker's flush steps. Chloramine in the supply can also show up, because it releases a little chlorine. Test with a kit that reads total chlorine, before the membrane and after each stage.
How do I know when DI resin is used up?
Some resins change colour as they are used up, but a TDS reading above zero after the DI stage is the clearer sign. Resin lasts less time when the membrane passes more dissolved material.
How often should I replace the RO membrane?
One water-treatment company quotes three to five years as normal, but it depends on how much you use it and on the water, and chlorine can ruin one far sooner. Replace it when rejection stays below the rating in its data sheet, not just by date.
Scape Eden community

Still stuck?

Describe the problem and share a photo in the WhatsApp community group. Other keepers can often spot what is wrong.

Sources

  1. DuPont FilmTec Reverse Osmosis Membranes Technical Manual (dechlorination, combined chlorine, effect of pressure, rejection formula)
  2. ALMAWATECH: Effects of free chlorine on reverse osmosis membranes
  3. UF/IFAS FA171: Dechlorination of municipal water

How we made this

Written with AI assistance from the sources listed here and checked against them (September 2026). Not yet reviewed by an expert. Report a mistake · How we write and check pages

Cite this page

Copy a ready-made line to credit this page in your own writing.

Citation

Scape Eden. “RO/DI water high TDS: why and how to fix it”. Scape Eden aquarium wiki, updated October 15, 2026. https://scapeeden.com/wiki/problems/ro-di-output-wrong

Reference style (APA)

Scape Eden. (2026, October 15). RO/DI water high TDS: why and how to fix it. Scape Eden. https://scapeeden.com/wiki/problems/ro-di-output-wrong

Plain link

https://scapeeden.com/wiki/problems/ro-di-output-wrong

Text and data compiled by Scape Eden are free to reuse under CC BY 4.0 with attribution (credit Scape Eden and link to this page). Photos keep their own credited licences. Records are AI-assisted drafts with cited sources: see how we write and check this.